...use Bank Change Messages in Korg Products
Most sequencers have an event edit mode, which allows inputting controller messages. Bank change messages require these events: Beat one, tick one: Controller 0 with its value - Beat one, tick two: Controller 32 with its value - Beat one, tick three: Program change. Make sure that Program Change and Exclusive filters are set to enable (ENA) to receive these commands.
Note: These listing covers all possible bank changes in the product lines specified for each chart. Since some models don't have all of the mentioned banks, some messages will not be received.
X Series/N364/264/Trinity Series/Triton Series/Z1/Z1EX
|
BANK A Message Value Controller 0 0 Controller 32 0 Program Change 0-99 (0-127) |
BANK B Message Value Controller 0 0 Controller 32 1 Program Change 0-99 (0-127) |
BANK C Message Value Controller 0 0 Controller 32 2 Program Change 0-99 (0-127) |
|
BANK D Message Value Controller 0 0 Controller 32 3 Program Change 0-99 (0-127) |
BANK E (Triton Only) Message Value Controller 0 0 Controller 32 4 Program Change 0-99 (0-127) |
BANK F (Triton Only) Message Value Controller 0 0 Controller 32 5 Program Change 0-99 (0-127) |
|
GM BANK Message Value Controller 0 56 Controller 32 0 Program Change 1-128 |
GM DRUM BANK Message Value Controller 0 62 Controller 32 0 Program Change * |
i-Series (i5, i5M i3, i2, i1, iX300, XC Series)
|
BANK A/B Message Value Controller 0 0 Controller 32 0 Program Change 0-127 (Numbers: 0-63 = A11-A88, 64-127 = B11-88) |
BANK C/D Message Value Controller 0 0 Controller 32 1 Program Change 0-127 (Numbers: 0-63 = C11-C88, 64-127 = D11-D88) |
BANK E/F,User Message Value Controller 0 0 Controller 32 2 Program Change 0-127 (Numbers: 0-63 = E11-E88, 64-127 = F11-F88) |
DRUMS Dr1-Dr8 Message Value Controller 0 0 Controller 32 3 Program Change 0-7 (Numbers: 0-7 = Dr1-Dr8) |
iS-Series/i40M
|
BANK A/B Message Value Controller 0 0 Controller 32 0 Program Change 0-127 (Numbers: 0-63 = A11-A88, 64-127 = B11-88) |
BANK C/D Message Value Controller 0 0 Controller 32 1 Program Change 0-127 (Numbers: 0-63 = C11-C88, 64-127 = D11-D88) |
BANK E/F User-Drum Message Value Controller 0 0 Controller 32 2 Program Change 0-127 (Numbers: 0-63 = E11-E88, 64-127 = F11-F88) |
I30
|
BANK A/B Message Value Controller 0 0 Controller 32 0 Program Change 0-127 (Numbers: 0-63 = A11-A88, 64-127 = B11-88) |
BANK C/D Message Value Controller 0 0 Controller 32 1 Program Change 0-127 (Numbers: 0-63 = C11-C88, 64-127 = D11-D88) |
BANK E Message Value Controller 0 0 Controller 32 2 Program Change 0-63 (Numbers: 0-63 = E11-E88) |
|
BANK F Message Value Controller 0 0 Controller 32 3 Program Change 0-63 (Numbers: 0-63 = F11-F88) |
BANK G Message Value Controller 0 0 Controller 32 3 Program Change 64-127 (Numbers: 64-127 = G11-G88) |
BANK R (Drums) Message Value Controller 0 0 Controller 32 4 Program Change 0-127 |
GM Drum Bank Program Change Conversion
Program Changes -- Drum Kits
|
00 - 15 -- Dr 11 16 - 17 -- Dr 12 25 -- Dr 13 32 - 39 -- Dr 14 40 -47 -- Dr 15 64 - 71 -- Dr 16 26 - 31 -- Dr 17 48 - 55 -- Dr 18 |
120 -- Dr 21 121 -- Dr 22 122 -- Dr 23 123 -- Dr 24 124 -- Dr 25 125 -- Dr 26 126 -- Dr 27 127 -- Dr 28 |
N5EX/N1/N1R/NS5R/NX5R Bank Changes
|
Bank |
Bank Select |
|
Name |
(MSB:LSB) |
|
GM-a |
00:00(GS/XG) |
|
00:01(GS) |
|
|
r:01 |
01:xx |
|
r:02 |
02:xx |
|
r:03 |
03:xx |
|
r:04 |
04:xx |
|
r:05 |
05:xx |
|
r:06 |
06:xx |
|
r:07 |
07:xx |
|
r:08 |
08:xx |
|
r:09 |
09:xx |
|
r:10 |
10:xx |
|
r:11 |
11:xx |
|
r:16 |
16:xx |
|
r:17 |
17:xx |
|
r:18 |
18:xx |
|
r:19 |
19:xx |
|
r:24 |
24:xx |
|
r:25 |
25:xx |
|
r:26 |
26:xx |
|
r:32 |
32:xx |
|
r:33 |
33:xx |
|
r:40 |
40:xx |
|
r:CM |
125:xx |
|
127:xx(GS) |
|
|
y:01 |
00:01(XG) |
|
y:03 |
0:03 |
|
y:06 |
0:06 |
|
y:08 |
0:08 |
|
y:12 |
00:12 |
|
y:14 |
00:14 |
|
Bank |
Bank Select |
|
Name |
(MSB:LSB) |
|
y:16 |
0:16 |
|
y:17 |
0:17 |
|
y:18 |
0:18 |
|
y:19 |
0:19 |
|
y:20 |
0:20 |
|
y:24 |
0:24 |
|
y:25 |
0:25 |
|
y:27 |
00:27 |
|
y:28 |
00:28 |
|
y:32 |
0:32 |
|
y:33 |
0:33 |
|
y:34 |
0:34 |
|
y:35 |
0:35 |
|
y:36 |
0:36 |
|
y:37 |
0:37 |
|
y:38 |
0:38 |
|
y:39 |
0:39 |
|
y:40 |
0:40 |
|
y:41 |
0:41 |
|
y:42 |
00:42 |
|
y:43 |
00:43 |
|
y:45 |
00:45 |
|
y:64 |
0:64 |
|
y:65 |
0:65 |
|
y:66 |
0:66 |
|
y:67 |
0:67 |
|
y:68 |
0:68 |
|
y:69 |
0:69 |
|
y:70 |
0:70 |
|
y:71 |
0:71 |
|
y:72 |
0:72 |
|
Bank |
Bank Select |
|
Name |
(MSB:LSB) |
|
y:96 |
00:96 |
|
y:97 |
00:97 |
|
y:98 |
00:98 |
|
y:99 |
00:99 |
|
y100 |
00:100 |
|
y101 |
00:101 |
|
ySFX |
64:xx |
|
GM-b |
56:00 |
|
57:00(05) |
|
|
PrgU |
80:xx |
|
PrgA |
81:xx |
|
00:00(05) |
|
|
PrgB |
82:xx |
|
PrgC |
83:xx |
|
CmbU |
88:xx |
|
CmbA |
89:xx |
|
CmbB |
90:xx |
|
CmbC |
91:xx |
|
yDr1 |
126:xx |
|
yDr2 |
127:xx(XG) |
|
120:xx(XG) |
|
|
rDrm |
61:xx |
|
120:xx(GS) |
|
|
kDrm |
62:xx |
|
120:xx(05) |
|
|
**** |
63:xx |
* (GS) : after GS Reset
* (XG) : after XG System ON
* (05) : 05R/W Map
N Series Drum Banks
| yDr2' Bank (Bank MSB=127) Drum Kit List (Drum Bank) Program No. Drum Kit Name (PC# xxh) 1 (00h) Standard 2 (01h) Standard 9 (08h) Room 17 (10h) Rock 25 (18h) Electro 26 (19h) Analog 33 (20h) Jazz 41 (28h) Brush 49 (30h) Classic
'yDr1' Bank (Bank MSB=126) Drum Kit List (Drum Bank) Program No. Drum Kit Name (PC# xxh) 1 (00h) SFX 1 2 (01h) SFX 2 |
'rDrm' Bank (Bank MSB=61) Drum Kit List (Drum Bank) Program No. Drum Kit Name (PC# xxh) 1 (00h) STANDARD 2 (01h) STANDARD 9 (08h) ROOM 17 (10h) POWER 25 (18h) ELECTRONIC 26 (19h) ANALOG 27 (1Ah) DANCE 33 (20h) JAZZ 41 (28h) BRUSH 49 (30h) ORCHESTRA 50 (31h) ETHNIC 51 (32h) KICK&SNARE 57 (38h) SFX 128 (7Fh) C/M |
'kDrm' Bank (BankMSB=62) Drum Kit List (Drum Bank) Program No. Drum Kit Name (PC# xxh) 1(00h)...16(0Eh) GM Kit 17(10h)...24(17h) Power Kit 25(18h) Dance Kit 26(19h) Analog Kit 27(1Ah)...32(1Fh) Dance Kit 33(20h)...40(27h) Jazz Kit 41(28h)...48(2Fh) Brush Kit 49(30h)...56(37h) Orch Kit 57(38h)...64(3Fh) GM Kit 65(40h)...72(47h) Perc Kit 73(48h) User Kit 1 74(49h) User Kit 2 75(4Ah)..128(7Fh) GM Kit |